75 Ohm Drop Coaxial Cable
| Construction | |||
| Material | Diameter (mm) | ||
| Inner Conductor | CCS-Copper clad steel | 1.63 | |
| Insulation | Physically Foamed PE | 7.11 | |
| 1st Outer conductor | Bonded aluminum laminated tape | ||
| 2nd Outer conductor | Al-Mg or copper alloy braid, Coverage: ≥60% | 16/6/0.16mm | |
| 3rd Outer conductor | Aluminum laminated tape (non-bonded) | ||
| 4th Outer conductor | Non-dripping flooding compound | ||
| Jacket | PVC, PE or flame retardant PVC, PE | 10.16 | |
| Mechanical Properties | |||
| Cable length | m | 305 | |
| Min. single bending radius | mm | 50 | |
| Pulling strength | N | 384 | |
| Adhesion Force | N | >60 | |
| Electrical Characteristics | |||
| Impedance (Ω) | 75 ± 3 | ||
| Nominal Capacitance (pF/m) | 54 | ||
| Velocity of Propagation (%) | 84 | ||
| DC breakdown voltage (kV) | 4.0 | ||
| Insulation resistance (MΩ*km) | ≥ 5000 | ||
| Screening attenuation (dB) | ≥ 85@30~1000MHz | ||
| Return Loss | |||
| 5-1000 MHz (dB) | ≥ 20 | ||
| 1000-2000 MHz (dB) | ≥ 20 | ||
| Attenuation (@ 20oC) | |||
| Frequency (MHz) |
Attenuation (dB/100m) |
Attenuation (dB/100ft) |
|
| 55 | 3.15 | 0.96 | |
| 211 | 6.23 | 1.90 | |
| 300 | 7.38 | 2.25 | |
| 450 | 9.02 | 2.75 | |
| 550 | 9.97 | 3.04 | |
| 750 | 11.97 | 3.65 | |
| 865 | 13.05 | 3.98 | |
| 1000 | 14.27 | 4.35 | |
| Standards | |||
| 2011/65/EU | Complian | ||
Tag :