Cáp Feeder Hansen RF50Z-1/2"
CONSTRUCTION |
||
Inner conductor |
Copper Clad Aluminum |
Φ4.80±0.03mm |
Insulation |
Physically foamed PE |
Φ12.20±0.30mm |
Outer conductor |
Ring corrugated copper |
Φ13.70±0.20mm |
Jacket |
Flame retardant black PE |
Φ15.60±0.25mm |
MECHANICAL PROPERTIES |
||
Min. single bending radius |
mm |
125 |
Maximum tensil strength |
N |
≥1130 |
Recommended maximum clamp spacing |
m |
1 |
ELECTRICAL PROPERTIES |
||
Impedance |
Ω |
50±2 |
Nominalcapacitance |
pF/m |
76 |
Nominal inductance |
µH/m |
0.19 |
Propagationvelocity |
% |
86 |
DC breakdown voltage |
kV |
4 |
Insulationresistance |
MΩ•km |
>5000 |
Peak power rating |
kW |
40 |
Cut-off frequency |
GHz |
8.8 |
Screening attenuation |
dB |
>120 |
ELECTRICAL PROPERTIES |
||
Impedance |
Ω |
50±2 |
Nominalcapacitance |
pF/m |
76 |
Nominal inductance |
µH/m |
0.19 |
Propagationvelocity |
% |
86 |
DC breakdown voltage |
kV |
4 |
Insulationresistance |
MΩ•km |
>5000 |
Peak power rating |
kW |
40 |
Cut-off frequency |
GHz |
8.8 |
Screening attenuation |
dB |
>120 |
TRANSMISSION PROPERTIES |
||
Frequency |
Attenuation |
Power |
MHz |
20℃, dB/100m(dB/100ft) |
20℃, kW |
100 |
2.17(0.66) |
3.49 |
450 |
4.75(1.45) |
1.59 |
690 |
5.97(1.82) |
1.34 |
800 |
6.46(1.97) |
1.17 |
900 |
6.85(2.09) |
1.1 |
1000 |
7.28(2.22) |
1.04 |
1800 |
10.10(3.08) |
0.75 |
2000 |
10.70(3.26) |
0.71 |
2200 |
11.24(3.43) |
0.65 |
2400 |
11.78(3.59) |
0.62 |
2500 |
12.06(3.68) |
0.61 |
2600 |
12.34(3.76) |
0.6 |
2700 |
12.61(3.84) |
0.59 |
3000 |
13.40(4.09) |
0.57 |
VSWR |
||
690-960MHz |
≤ |
1.15 |
1700-2200MHz |
≤ |
1.15 |
2300-2400MHz |
≤ |
1.15 |
2500-2690MHz |
≤ |
1.15 |
ENVIRONMENTAL PROPERTIES |
||
2011/65EU(ROHS) |
Compliant |
Cáp Feeder Hansen RF50Z-1/2"