Cáp Feeder 7/8" Hengxin HCTAYZ-50-22
| CONSTRUCTION MATERIALS | |||
| Inner conductor | Smooth Copper Tube | ||
| Dielectric | Physical Foam Polyethylene | ||
| Outer conductor | Corrugated Copper Tube | ||
| Jacket | Low Smoke Halogen-free Fire-retardant | ||
| PHYSICAL DIMENSIONS | |||
| Inner Conductor Diameter | 9.00 mm | ||
| Dielectric Diameter | 22.30 mm | ||
| Outer Conductor Diameter | 24.90 mm | ||
| Diameter Over Jacket | 27.50 mm | ||
| MECHANICAL SPECIFICATIONS | |||
| Minimum Bending Radius | |||
| Single Bending | 90 mm | ||
| Repeated Bending | 250 mm | ||
| Minimum Number of Bends | 15 | ||
| Tensile Strength | 1470 N(325 lb) | ||
| ELECTRICAL PROPERTIES | |||
| Capacitance | 75.0 pF/m(22.9 pF/ft) | ||
| Impedance | 50±1 Ω | ||
| Velocity | 89% | ||
| RF Peak Voltage | 3.00 kV | ||
| Peak power rating | 91 kW | ||
| Cut-off frequency | 5.20 GHz | ||
| Shielding Effectiveness >10MHz | >120 dB | ||
| Insulation Resistance | 5000 MΩ•km | ||
| VSWR | |||
| 800~1000MHz | ≤1.10 | ||
| 1700~2200MHz | ≤1.13 | ||
| 2200~2700MHz | ≤1.15 | ||
| ENVIRONMENTAL SPECIFICATION | |||
| Storage Temperature | -55 ℃ ~ +85 ℃ | ||
| Installation Temperature | -40 ℃ ~ +60 ℃ | ||
| Operating Temperature | -55 ℃ ~ +85 ℃ | ||
| TRANSMISSION PROPERTIES | |||
| Frequency | Attenuation | Average | |
| MHz | dB/100 m | dB/100 ft | Power Rating (kW) |
| 100 | 1.19 | 0.36 | 8.62 |
| 150 | 1.47 | 0.45 | 7.20 |
| 200 | 1.71 | 0.52 | 5.99 |
| 280 | 2.05 | 0.62 | 4.94 |
| 450 | 2.64 | 0.80 | 3.88 |
| 800 | 3.62 | 1.10 | 2.83 |
| 900 | 3.87 | 1.18 | 2.65 |
| 1000 | 4.10 | 1.25 | 2.50 |
| 1500 | 5.16 | 1.57 | 1.99 |
| 1800 | 5.73 | 1.75 | 1.79 |
| 2000 | 6.09 | 1.86 | 1.68 |
| 2200 | 6.44 | 1.96 | 1.59 |
| 2400 | 6.78 | 2.07 | 1.54 |
| 2500 | 6.95 | 2.12 | 1.50 |
| 3000 | 7.74 | 2.36 | 1.33 |
Cáp Feeder 7/8" Hengxin HCTAYZ-50-22