| SPECIFICATIONS | |
| Applicable Fibers | SM, MM, DSF, NZD, EDF, BIF/UBIF (Bend insensitive fiber) |
| Cladding Diameter | 80~150 μm |
| Coating Diameter | 100~1,000 μm |
| Fiber Cleave Length | 5~16 mm |
| Average Splice Loss | SM: 0.02 dB, MM: 0.01 dB, DSF: 0.04 dB, NZD: 0.04 dB |
| Splice Time | 7 seconds (semi-auto mode) 9 seconds (regular mode) |
| Heat Time | 25 seconds*6 (S922: 40 mm Sleeve, S921: 60 mm Sleeve) (Pre-heat mode) 31 seconds*6 (S922: 40 mm Sleeve, S921: 60 mm Sleeve) (regular mode) |
| Splice Programs | Max. 150 |
| Automatic Splicing Selection | SM: SM, DSF, NZD, BIF/UBIF, MM: MM |
| Heat Programs | Max. 18 |
| Automatic Heating Start | Available |
| Applicable Sleeves | 20/40/60 mm |
| Fiber Holding | Tight holder (Loose tube applicable) or Removal Fiber Holder System |
| Tension Test | 1.96 N |
| Return Loss of Splice | 60 dB or greater |
| Attenuation Splice Function | Intentional high splice loss of 0.1 dB to 10 dB (0.1 dB step) can be made for an inline fixed attenuator |
| Fiber Image Magnification | 304X, 608X |
| Splice Memory | Max. 2,000 |
| Image Capture Capacity | Last 100 images to be automatically captured + Up to 24 images to be stored permanently |
| Dimension | 127W × 199D × 105H mm (not including shock absorber) 159W × 231D × 130H mm (including shock absorber) |
| Weight | 1.9 kg (without battery) |
| 2.3 kg (with two batteries) | |
| Monitor | 3.5” color LCD monitor |
| Data Output | USB ver.2.0 mini |
| Battery Capacity | Typical 80 splice/heat cycles with single battery*7 Typical 200 splice/heat cycles with 2 batteries*8 |
| Altitude | 5,000 mh |
| Wind Protection | Max. wind velocity of 15 m/s. |
| Operating Temperature | -10 to +50°C (0 to 95% Relative Humidity [Non-Condensing]) |
| Storage Temperature | -40 to +60°C (0 to 95% Relative Humidity [Non-Condensing]) |
| Humidity | 0 to +95% RH (non-condensing) |
| Power Source | AC Input 100 to 240 V (50/60 Hz), DC Input 11 to 17 V without any change of hardware |